数位合成函数信号产生器
【型 号】SFG-1013
【品 牌】台湾固纬GWINSTEK
【价 格】洽询
【主要技术指标】Frequency Range:0.1Hz~3MHz
【详细技术指标】
简单介绍 · DDS
Technology and FPGA Chip Design · Frequency Range:0.1Hz~3MHz · High
Frequency Accuracy : ∮ 20ppm · High Frequency Stability : ∮ 20ppm · Max.
Frequency Resolution :100mHz · Low Distortion Sine Wave:-55dBc,0.1Hz~200kHz
· Voltage Display
SFG-1013
数位合成函数信号产生器的详细介绍
SFG-1000
Series, an economic function generator with high accuracy and high
stability output, is designed based on the DDS (Direct Digital
Synthesized) technology embedded in a large scale FPGA. The frequency
range of 3MHz and the output waveform selection of Sine, Square, Triangle
and TTL of SFG-1000 Series adequately provide the fundamental features
to ensure high confidence for the test results. The DDS technology at
an affordable price gives a high value solution to the users who need a
signal source for accurate but unsophisticated measurement
applications. |
MAIN |
Output
Function |
Sine,
Square, Triangle |
Frequency
Range (For Sine, Square) |
0.1Hz~3MHz |
Frequency
Range (For Triangle) |
0.1Hz~1MHz |
|
0.1Hz
Maximum |
Frequency
Stability |
∮ 20 ppm |
Frequency
Accuracy |
∮ 20 ppm
|
Frequency
Aging |
∮ 5 ppm /
year |
Amplitude
Range |
10Vp-p
(into 50?load) |
|
∮20% at
maximum position |
Impedance |
50?∮10? |
Attenuator |
-40dB∮1dB⊙1 |
DC
Offset |
≌-5V°≈+5V(into
50?load) |
Duty
Control Range |
25% to
75% below 1MHz (Square wave only) |
Display |
6-digit
LED display |
Output
Control |
ON/OFF
selector |
SINE WAVE |
Harmonics
Distortion |
From
Amplitude control at maximum position without any attenuation to its
1/10 of any combination setting, TTL OFF -55dBc, 0.1Hz ~
200kHz -40dBc, 0.2MHz ~ 2MHz -35dBc, 2MHz ~ 3MHz
|
Flatness
(at maximum amplitude relative to 1kHz) |
≌∮0.3dB,
0.1Hz ~ 1MHz ≌∮0.5dB,
1MHz ~ 2MHz ≌∮ 1dB,
2MHz ~ 3MHz |
TRIANGLE
WAVE |
Linear |
≠98?,0.1Hz°100kHz;≠95?,100kHz°1MHz
|
PSQUARE
WAVE |
Symmetry |
5% of
period +4ns to 0.1Hz°100kHz |
Rise or
Fall Time |
∝100ns at
maximum output. (into 50?load) |
TTL
OUTPUT |
Level |
≠3Vpp |
Fan
Out |
20 TTL
load |
Rise or
Fall Time |
∝25ns |
General |
Operation
Environment |
Indoor
use, altitude up ~ 2000m Ambient Temperature 0? ~ 40? Relative
Humidity: Up to 80% at 0~ 40? Up to 70% at 35? ~ 40? Installation
category II Pollution Degree 2 |
POWER
SOURCE |
|
AC
240V/220V/110V∮10%,
50/60Hz |
STORAGE
CONDITION |
Temperature
|
-10? ~
70? |
Humidity |
70%
(Maximum) |
ACCESSORIES
|
|
User
manual ⊙
1 Power Cord x 1 GTL-101⊙
1 |
DIMENSION
& WEIGHT |
251(W)⊙91(H)⊙291(D)
mm Approx. 2.1kg | |
,
,